Technical Reference · A–Z Terminology

Water Filtration & RO Engineering Glossary

Clear, accurate definitions for water chemistry measurements, membrane mechanics, pump control switches, and international certification standards.

Water Chemistry & Metrics

TDS (Total Dissolved Solids)

Combined weight of inorganic salts (calcium, magnesium, sodium, bicarbonates, chlorides) and small organics dissolved in water, measured in ppm or mg/L.

Engineering Note: Handheld TDS meters infer TDS from electrical conductivity (EC). Low TDS does NOT guarantee zero bacteria or zero uncharged organics.

Open related spec →

PPM (Parts Per Million)

Standard concentration unit in dilute water testing where 1 ppm equals 1 milligram of dissolved solid per liter of water (mg/L).

Engineering Note: Ultra-trace toxins like PFAS and lead sit 1,000x–1,000,000x smaller in ppb (parts per billion) or ppt (parts per trillion).

Open related spec →

TDS Creep

Harmless rise in initial permeate TDS after an RO purifier sits idle while raw feed pressure balances across a semi-permeable membrane.

Engineering Note: Test membrane health ONLY after opening the faucet for 90 seconds with the storage tank valve closed so fresh permeate flushes stagnant creep.

Open related spec →

Water Hardness (CaCO₃)

Concentration of dissolved divalent calcium (Ca²⁺) and magnesium (Mg²⁺) ions expressed as mg/L CaCO₃ or Grains Per Gallon (1 GPG = 17.1 ppm).

Engineering Note: Water above 180 mg/L creates brisk kettle crust and gypsum scaling inside RO membrane concentrate channels unless feed recovery is controlled.

Open related spec →

Langelier Saturation Index (LSI)

Thermodynamic water balance index predicting whether water will deposit calcium carbonate scale (+LSI) or corrode metal plumbing (−LSI).

Engineering Note: Commercial BWRO plant designers adjust antiscalant dosing or acid pH injection whenever concentrate LSI climbs positive inside the final 4040/8040 element.

Open related spec →

Turbidity (NTU)

Cloudiness of water caused by suspended silt, clay, algae, or oxidized iron scattering light, measured in Nephelometric Turbidity Units.

Engineering Note: High turbidity blinds UV-C lamps and chokes 5 µm sediment filters—turbid borewells require FRP multimedia or staged 20->5 µm pre-treatment.

Open related spec →

PFAS ("Forever Chemicals")

Synthetic per- and polyfluoroalkyl carbon-fluorine compounds (PFOA, PFOS, GenX) resistant to environmental degradation and boiling.

Engineering Note: Requires extruded catalytic activated carbon (NSF 53) and/or 0.0001 µm Reverse Osmosis (NSF 58) for reliable >95% removal.

Open related spec →

Chloramine vs Free Chlorine

Long-lasting municipal disinfectant formed by bonding chlorine with ammonia (NH₂Cl) to reduce trihalomethane byproducts in long pipelines.

Engineering Note: Unlike free chlorine, chloramine cannot off-gas easily and requires slower-contact catalytic carbon blocks ahead of TFC RO membranes.

Open related spec →

pH (Potential of Hydrogen)

Logarithmic scale from 0 to 14 measuring acidity (<7) vs alkalinity (>7) of drinking water.

Engineering Note: Fresh un-buffered RO permeate drops gently to pH 6.2–6.7 because dissolved CO₂ gas passes the membrane cleanly; alkaline post-filters buffer pH back toward 7.2–8.2.

Open related spec →

Membrane & Filtration Physics

Reverse Osmosis (RO)

Pressure-driven separation pushing water molecules through a 0.0001 micron semi-permeable film against natural osmotic pressure to reject 94%–99% of salts.

Engineering Note: Continuous cross-flow concentrate draining is essential to sweep rejected salts away from the membrane surface.

Open related spec →

Thin-Film Composite (TFC) Polyamide

Modern spiral-wound three-layer RO sheet pairing a porous polysulfone base with an ultra-thin ~0.2 µm aromatic polyamide salt-rejecting skin.

Engineering Note: Delivers high flow at low pressure (~60–100 psi) but has ZERO tolerance for free chlorine—carbon pre-stages are mandatory.

Open related spec →

Ultrafiltration (UF · 0.01–0.02 µm)

Non-electric hollow-fiber physical sieve blocking 99.99% of bacteria, cysts, and turbidity while letting natural dissolved salts pass untouched.

Engineering Note: Ideal zero-waste choice for clean low-TDS municipal tap (<200–250 ppm) where desalination is unnecessary.

Open related spec →

Nanofiltration (NF)

Loose-pore spiral membrane (~0.001 µm) sitting between UF and RO that rejects divalent hardness (Ca²⁺, Mg²⁺, sulfates) while passing moderate monovalent minerals.

Engineering Note: Often used for softening high-hardness surface water with moderate TDS retention at slightly lower pressures than BWRO.

Open related spec →

Salt Rejection %

Percentage of incoming dissolved salts blocked by an RO membrane, calculated as ((Feed TDS − Permeate TDS) / Feed TDS) × 100.

Engineering Note: Healthy 1812 TFC elements maintain 92%–98% salt rejection; inspect seals and replace membranes once rejection drops below ~88%–90%.

Open related spec →

Permeate vs Concentrate (Reject / Brine)

Permeate is the purified low-TDS drinking stream exiting the center membrane core; Concentrate is the high-TDS reject water flushing salts down the drain.

Engineering Note: Concentrate carries 1.3x–3x incoming salt concentration—reusing reject water safely for mopping or hardy landscaping avoids plumbing waste.

Open related spec →

Micron Rating (Nominal vs Absolute)

Physical pore diameter measured in micrometers (1 µm = 0.001 mm); Nominal captures ~85% at rating while Absolute captures >=99.9%.

Engineering Note: Stage 1 uses 5 µm sediment (never 1 µm directly on muddy wells) to protect downstream pumps without premature pressure choke.

Open related spec →

CTO Block vs GAC Granular Carbon

GAC uses loose granular coconut carbon inside a shell; CTO extrudes powdered carbon with binders into a dense solid block resisting channeling.

Engineering Note: CTO blocks offer tight 0.5–5 µm particulate + superior chlorine/PFAS contact, whereas GAC excels for high-flow odor capture.

Open related spec →

Membrane Chevron Brine Seal

Lip-shaped rubber U-cup gasket wrapped around one end of every 1812–8040 spiral element forcing feed water INSIDE the membrane leaves rather than bypassing along the housing wall.

Engineering Note: Always face the open chevron lip UPSTREAM toward the incoming raw water feed cap; missing or folded seals spike pure TDS immediately.

Open related spec →

Osmotic Pressure

Natural thermodynamic pressure driving pure water across a membrane toward salty water (~1 psi per ~100 ppm TDS), which booster pumps must overcome.

Engineering Note: 1,000 ppm brackish water exerts ~10 psi osmotic push-back; 35,000 ppm ocean seawater exerts ~380+ psi before producing permeate.

Open related spec →

Pumps, Valves & Hydraulics

GPD (Gallons Per Day) & LPH (Liters Per Hour)

Membrane production throughput ratings: domestic systems specify 50–1,000 GPD (~8–155 LPH) while commercial plants rate 250–10,000+ LPH.

Engineering Note: Actual winter output typically runs 25%–35% slower than 25 °C lab nameplate ratings due to colder water viscosity.

Open related spec →

Recovery Rate (Pure-to-Drain Ratio)

Percentage of feed water converted into clean permeate: Recovery % = (Permeate Flow / Total Feed Flow) × 100.

Engineering Note: Household RO typically targets 20%–35% recovery (3:1 to 2:1 waste-to-pure) specifically to prevent gypsum scaling on hard water.

Open related spec →

Capillary Flow Restrictor (cc/min)

Precision-bored orifice inserted on the membrane concentrate line to create 60–90 psi back-pressure across TFC sheets while metering reject flow.

Engineering Note: Must match membrane GPD strictly (e.g., 300cc for 50 GPD, 420cc for 75 GPD, 550cc for 100 GPD) and be replaced alongside every new membrane.

Open related spec →

Auto Shut-Off Valve (ASOV)

Mechanical 4-port diaphragm valve closing raw inlet water automatically once pure tank back-pressure reaches ~60%–65% of feed pressure without electricity.

Engineering Note: Requires a healthy working check valve downstream; torn internal rubber ASOV diaphragms cause nonstop sink drain leaks.

Open related spec →

Low-Pressure (LPS) & High-Pressure Switches (HPS)

Safety micro-switches wiring 24V booster pumps: LPS protects pump heads if incoming tap water fails (<5 psi); HPS cuts power cleanly at ~38–45 psi tank full.

Engineering Note: Mount HPS downstream of the membrane check valve on the tank tee—never upstream where shutoff pressure vanishes.

Open related spec →

One-Way Check Valve

Spring-loaded non-return poppet fitted inside the membrane pure permeate elbow keeping pressurized storage tank water from flowing backward toward drain.

Engineering Note: A stuck or grit-fouled $3 check valve is the #1 culprit behind constant booster pump cycling every 60 seconds.

Open related spec →

Solenoid Shut-Off Valve (24V DC / 220V AC)

Electromagnetic coil valve opening incoming feed water only while energized with the booster pump, sealing off positive feed waste when tank fills.

Engineering Note: Silt trapped under the brass/nylon plunger lets drain water drip endlessly even after unplugging the RO power brick.

Open related spec →

24V DC Diaphragm Booster Pump

Self-priming positive-displacement 3-chamber wobble-plate pump raising weak tap/gravity inlet pressure up to 70–100+ psi across domestic RO membranes.

Engineering Note: Match adapter amperage (1.5A–5A) and pump open-flow GPD to membrane size; sand scratches rubber pump valves cleanly preventable by Stage 1 PP.

Open related spec →

Bladder Tank Air Pre-Charge (5–7 PSI)

Clean captive butyl-rubber air cushion pressurized inside the lower shell chamber behind purified water to push fast faucet flow without a pump.

Engineering Note: Measure via bottom Schrader valve ONLY when the tank is completely drained empty! 0 psi bladder air causes slow trickle after half a cup.

Open related spec →

Antiscalant / Siliphos Scale Inhibitor

Food-grade polyphosphate or polymeric threshold agent disrupting calcium carbonate, sulfate, and silica crystal growth inside concentrate spacers.

Engineering Note: Essential in commercial 250–10,000 LPH BWRO plants and >1,000 ppm borewell installs to prevent irreversible gypsum membrane scaling.

Open related spec →

FRP Media Tank & 4040/8040 Pressure Vessel

Corrosion-proof Fiberglass-Reinforced Plastic cylinders housing loose backwash sand/carbon beds (vertical tanks) or high-pressure RO elements (4040/8040 horizontal shells).

Engineering Note: Load granular sand/carbon media only to 60%–65% vessel height so upward backwash expansion lifts silt cleanly without dumping media.

Open related spec →

Differential Pressure (ΔP)

Pressure drop measured between feed inlet and outlet across a cartridge filter or RO pressure vessel array.

Engineering Note: Swap 20" Big Blue pre-filters immediately when ΔP crosses 12–15 psi; clean commercial RO elements chemically before array ΔP doubles baseline.

Open related spec →

Standards & Certifications

NSF/ANSI 42 (Aesthetic Reduction)

Third-party standard certifying taste, free chlorine odor, and non-health nominal particulate class reduction.

Engineering Note: Does NOT certify reduction of lead, arsenic, PFAS, fluoride, or microbes—verify NSF 53/58 separately for health claims.

Open related spec →

NSF/ANSI 53 (Health Effects)

Strict health standard validating point-of-use reduction of lead, Cryptosporidium/Giardia cysts, VOCs, chloramines, and specific PFAS.

Engineering Note: Sub-micron extruded CTO/catalytic carbon blocks meeting NSF 53 achieve >99% lead & cyst capture at line pressure.

Open related spec →

NSF/ANSI 58 (Point-of-Use Reverse Osmosis)

Certification standard governing RO desalination efficiency, arsenic (As V), fluoride, nitrate reduction, and pressure housing cyclic durability.

Engineering Note: Includes strict structural pressure-surge fatigue testing to prevent plastic bowl blowouts under sink cabinets.

Open related spec →

NSF/ANSI 401 (Emerging Contaminants)

Protocol validating filtration of trace trace-level pollutants including bisphenol A (BPA), microplastics, OTC pharmaceuticals, and herbicides.

Engineering Note: Modern multi-stage RO units combine NSF 53/401 catalytic carbon + NSF 58 TFC membranes for complete synthetic molecule barrier coverage.

Open related spec →

NSF/ANSI 55 (UV Microbiological Water Treatment)

UV disinfection standard splitting Class A (>=40 mJ/cm² UV-C dose for unsafe well water) from Class B (>=16 mJ/cm² supplemental taste/nuisance guard).

Engineering Note: Valid only when pre-filtered water clarity maintains high UV transmittance across clean quartz glass sleeves.

Open related spec →