Solenoid Shut-off Valve
Stage 3 · Pumping & controlService window: 36–60 months

Solenoid Shut-off Valve

Closes the feed line when the pump stops, so the drain stops too.

An electric gate that opens only while the pump runs. When the tank is full the pump stops, the valve closes and no more water flows to drain.

Key Technical Specs

TypeNormally closed
Supply24 V DC, wired in parallel with the pump
Connection1/4 in quick-connect
SitsFeed line, ahead of the pump

4-Step Service & Replacement

  1. 1Shut mains water supply and unplug electrical power completely.
  2. 2Verify the embossed inlet-to-outlet flow arrow before cutting/pushing tubing.
  3. 3Wire the two 24V coil leads in parallel directly across the booster pump.
  4. 4Wait 2 minutes after tank cutoff to verify drain flow drops to zero.

Related Symptoms & Faults

Drain Water Never Stops

Waste water keeps running to the sink drain hours after the tank should be full.

Common Questions

Are 24V DC RO solenoid leads polarity sensitive?

Standard electromagnetic RO coils are non-polarized—either lead works on positive or negative.

Should a unit use both a solenoid valve and a mechanical ASOV?

No. Pumped units use a 24V solenoid + HPS; non-electric units use a 4-way mechanical ASOV.