Raw Water Centrifugal Pre-Feed & Borewell Submersible Pumps

Raw Water Centrifugal Pre-Feed & Borewell Submersible Pumps

30–60 PSI raw transfer & borewell pumps sized for BOTH RO feed and high-GPM FRP backwash cycles.

Supplies continuous positive feed pressure from deep boreholes or raw ground tanks through multimedia sand, activated carbon, and water softener vessels into RO skids—engineered to deliver both steady RO service flow and the much higher peak GPM velocity needed to fluidize FRP backwash beds.

Common Size / Rating Options
0.5 HP1.0 HP1.5 HP2.0 HP

Application Scale & Replacement Verification

Scale: Commercial ROBrand: Engineering Family

Compare housing dimensions, port diameter, and membrane GPD capacity before ordering spares or requesting local dealer quotes. Verify System Fit in Water Planner →

Before You Install: Mount surface centrifugal feed pumps below water level (flooded suction) wherever possible, or fit a large brass/SS foot valve + check valve on the suction pipe so priming never drops overnight.

Key Technical Specs

Engineering CategoryCommercial RO · Raw Water Feed & Backwash Pumps
Field Variants Tracked168 dimensional & pressure configurations
Industry StandardsCE · ISO 9906 · NSF 61 SS Wetted
TypeHorizontal SS304 Centrifugal Feed Pump, Horizontal SS316 Brackish Feed Pump, 4-Inch Deep-Well Bore Submersible SS304
Hp0.5 HP, 1.0 HP, 1.5 HP, 2.0 HP (+3 more)
Voltage110/220V 1-Phase, 380-415V 3-Phase
Port1" NPT/BSP, 1.25" NPT/BSP, 1.5" NPT/BSP, 2" Flange

Right Fit When

  • Borewell extraction and raw ground storage tanks feeding commercial 8×44 to 36×72 FRP media trains.
  • Systems protected by tank float switches and spring-loaded suction foot valves.
  • Field aliases & trade names: Raw Water Feed Pump, Backwash Transfer Pump, SS304 Horizontal Centrifugal, Borewell Pump.
  • Engineered to CE, ISO 9906, NSF 61 SS Wetted criteria where applicable.

When To Skip or Double-Check

  • Never size a feed pump strictly by RO permeate LPH alone—check the peak backwash GPM of your largest FRP tank (often 2–3× service flow!) so sand beds actually expand and clean.

Signs This Part Is Failing

  • Low backwash lift leaving media tanks fouled
  • Dry-run motor burnout (missing float switch)
  • Impeller rust lock in cast-iron units

Diagnostic Checklists If Something Goes Wrong

Step 1 · Diagnose lost prime & suction air leaks

Does the surface feed pump spin smoothly with zero pressure lifting into FRP tanks?

Unscrew top priming plug: empty casing proves suction check/foot valve leaked down overnight.

Common Questions

Why does a sand tank need a bigger feed pump than an RO membrane alone?

Backwashing a 16×65 sand tank needs ~20–25 GPM upward velocity to lift gravel/sand clean, whereas a 1,000 LPH RO feed only pulls ~8–10 GPM.

Cast iron vs stainless steel surface feed pumps—which is better for RO?

Choose SS304 wet-end centrifugal pumps so internal rust flakes never load up downstream 5 µm Jumbo guard filters.

More in Multistage & Dosing Pumps