LLASPA Automatic Pump Control Switch (Water Pump Pressure Controller)

LLASPA Automatic Pump Control Switch (Water Pump Pressure Controller)

Automatic flow-and-pressure pump controller protecting commercial transfer pumps from dry running while automating start/stop.

Replaces bulky pressure tanks and mechanical pressure switches on raw transfer and delivery pumps. Senses water flow and line pressure simultaneously—cutting power instantly when tanks run dry and restarting smoothly whenever a downstream valve opens.

Application Scale & Replacement Verification

Scale: Commercial / IndustrialBrand: Axtron

Compare housing dimensions, port diameter, and membrane GPD capacity before ordering spares or requesting local dealer quotes. Verify System Fit in Water Planner →

Before You Install: Install dead-vertical with the flow arrow pointing up, never plumb an isolation check valve immediately downstream where it traps line pressure, and match starting pressure setting below building static head.

Key Technical Specs

System SeriesAxtron
Application DutyCommercial / Industrial
Wetted Hydraulic BodySS304 / SS316L Multistage Impeller Stack
Shaft Seal MaterialSilicon Carbide / Carbon Mechanical Seal

Right Fit When

  • 1HP–2HP single-phase raw water feed pumps and permeate delivery booster pumps up to ~10A.
  • Commercial skid feed lines needing automatic dry-run lockout without external float switches.

When To Skip or Double-Check

  • Skip direct connection on heavy 3-phase or >1.5 kW motors without wiring through a magnetic contactor relay.

Signs This Part Is Failing

  • Red Failure LED illuminates and pump refuses to restart until Reset is pressed (dry-run trip)
  • Pump cycles ON and OFF every 10–20 seconds with all downstream taps closed
  • Pump keeps running nonstop even after outlets shut off

Diagnostic Checklists If Something Goes Wrong

Step 1 · Diagnose red Failure / Dry-Run trip LED

Does the controller cut the pump off within 10 seconds of starting and light the Failure indicator?

Verify raw suction tank water is full, check foot valve prime, and press Restart.

Common Questions

Does this controller eliminate the need for a pressure tank?

For continuous flow delivery yes, though adding a small 2–5L expansion tank prevents cycling on tiny micro-drips.

Can it mount horizontally?

Most electronic pump controllers rely on a spring/gravity internal check valve and must mount vertically with the flow arrow pointing up.