Water Chemistry Test Kits, Strips & Silt Density Index (SDI) Apparatus
DPD free/total chlorine test kits, hardness/arsenic/silica strips & 15-minute SDI-15 fouling apparatus.
Verifies pre-RO chemical water threats that electronic TDS pens cannot see: DPD chlorine reagents confirm 0.00 ppm chlorine ahead of fragile membranes, hardness/silica/iron drop-count kits prevent irreversible scaling, and 0.45 µm Silt Density Index (SDI-15) kits quantify colloidal fouling risk on commercial skids.
Application Scale & Replacement Verification
Compare housing dimensions, port diameter, and membrane GPD capacity before ordering spares or requesting local dealer quotes. Verify System Fit in Water Planner →
Key Technical Specs
| Engineering Category | Testing & Maintenance · Chemical & SDI Test Kits |
|---|---|
| Field Variants Tracked | 24 dimensional & pressure configurations |
| Industry Standards | EPA / APHA Standard Methods · ASTM D4189 SDI |
| Parameter | Free & Total Chlorine (0-10 ppm), Total Water Hardness (Grains/gpg & mg/L), Dissolved Iron & Manganese, Hydrogen Sulfide (H2S) (+4 more) |
| Format | 50-Strip Bottle, 100-Test Drop-Count Titration Kit, Complete Portable Field Kit |
Right Fit When
- Commercial RO startup commissioning and routine daily/weekly operator QC logbooks.
- Homeowners screening well water for hardness, total/free chlorine, iron, pH, and arsenic.
- Field aliases & trade names: Hardness Test Kit, Chlorine Strips, SDI Test Kit, Iron/Arsenic/Nitrate Test Kit.
- Engineered to EPA / APHA Standard Methods, ASTM D4189 SDI criteria where applicable.
When To Skip or Double-Check
- Check reagent expiration dates strictly—expired DPD chlorine powders fail to turn pink even in chlorinated water, giving dangerous false confidence right before killing an RO membrane!
Signs This Part Is Failing
- Expired reagents giving false-negative chlorine tests (leading to membrane oxidation)
- Clogged 0.45µm SDI pads
Diagnostic Checklists If Something Goes Wrong
Did RO membranes oxidize rapidly even though daily chlorine checks looked clear?
Common Questions
What is a safe SDI-15 limit before feeding commercial 4040/8040 RO membranes?
Keep Silt Density Index (SDI-15) strictly below 3.0 (manufacturers allow up to 5.0 max, though >3.0 requires frequent chemical cleaning).
Free Chlorine vs Total Chlorine—which test matters for RO membranes?
Test TOTAL Chlorine! City utilities often switch to Chloramines (combined chlorine), which shows zero on "Free" chlorine strips while still chewing through TFC membranes.