Digital pH Meter (Portable pH Tester)

Digital pH Meter (Portable pH Tester)

Portable digital glass-bulb pH meter verifying drinking alkalinity (pH 6.0–8.5) and CIP chemical wash solutions (pH 2–12).

Measures hydrogen ion activity from 0.00 to 14.00 pH using a sensitive hydrated glass sensing bulb and automatic temperature compensation (ATC). Essential both for verifying post-RO alkaline mineral cartridges and checking acid/caustic CIP solution targets on commercial RO plants.

Application Scale & Replacement Verification

Scale: Domestic / HomeBrand: Axtron

Compare housing dimensions, port diameter, and membrane GPD capacity before ordering spares or requesting local dealer quotes. Verify System Fit in Water Planner →

Before You Install: Soak a dried probe tip in pH 4.0 buffer (or KCl storage solution) for 30 minutes before calibrating, and gently stir in pure low-TDS RO water for 20 seconds since low-ion water responds slower than buffered tap water.

Key Technical Specs

System SeriesAxtron
Application DutyDomestic / Home
Sensor InterfaceCorrosion-Resistant Platinum / Alloy Electrodes
Compensation FeatureAutomatic Temperature Compensation (ATC)

Right Fit When

  • Checking alkaline remineralizer cartridge effectiveness (confirming pH lift from ~6.2 up to 7.5–8.5).
  • Commercial plant operators verifying CIP acid (pH 2.0–3.0) and caustic (pH 10.5–11.5) batches.

When To Skip or Double-Check

  • Never store a glass pH electrode inside pure 0-ppm RO/DI water or bone dry—pure water leaches internal KCl electrolyte out of the reference junction and kills the probe.

Signs This Part Is Failing

  • Screen reading floats aimlessly or refuses to stabilize even in tap water
  • pH reads identically across completely different alkaline and acidic solutions (cracked glass bulb)
  • Dim LCD or stuck calibration error from depleted LR44 button cells

Diagnostic Checklists If Something Goes Wrong

Step 1 · Run a 2-point buffer calibration check (pH 6.86 & 4.01)

Does the meter drift >0.3 pH away from known fresh buffer powder packets?

Dissolve fresh 6.86 and 4.01 packets in clean RO/distilled water at ~25°C, dip, and follow CAL procedure.

Common Questions

Why does a pH meter jump slowly when dipped into pure RO water?

Ultra-low-TDS water has almost zero buffering ions and absorbs CO2 from air instantly—stir gently and let the number settle 15–30 seconds.

Can one meter test both drinking water and commercial CIP acid washes?

Yes—just rinse thoroughly in clean tap water between extreme acid (pH 2) and alkaline (pH 11) checks and recalibrate afterward.