Lyson 4×40 TP Horizontal Centrifugal Pump (Stainless Steel Water Pump)

Lyson 4×40 TP Horizontal Centrifugal Pump (Stainless Steel Water Pump)

Lyson 4 m³/h (40-stage) Horizontal SS multistage RO pump (Three-Phase (380–415V AC)) generating 120–260 PSI membrane pressure.

Stacking 40 stainless steel impellers inside a horizontal SS304/SS316 hydraulic casing builds steady, pulse-free 4 m³/h high-pressure flow for 4040 and 8040 commercial RO vessels. Three-phase TP motor configuration pairs directly with VFD soft-starters to prevent water-hammer membrane telescoping.

Application Scale & Replacement Verification

Scale: Commercial / IndustrialBrand: Lyson

Compare housing dimensions, port diameter, and membrane GPD capacity before ordering spares or requesting local dealer quotes. Verify System Fit in Water Planner →

Before You Install: Crack the top bleed screw until solid water vents air-free, then bump-test motor start for 1 second to verify fan rotation matches the directional arrow—backward 3-phase spin cuts RO pressure in half!

Key Technical Specs

Manufacturer / SeriesLyson
Nominal Pump Rating4 m³/h · 40 Stages
Motor Electrical PhaseThree-Phase (380V)
Application DutyCommercial / Industrial

Right Fit When

  • Commercial/industrial 4040 & 8040 RO skids requiring 4 m³/h nominal flow at high brackish head.
  • Three-Phase (380–415V AC) electrical panels with upstream Low-Pressure Switch dry-run cutoff and 5 µm Jumbo guard filters.

When To Skip or Double-Check

  • Verify 3-phase 380–415V site supply before ordering a TP model—it cannot run directly on residential 220V single-phase without a dedicated VFD phase converter.

Signs This Part Is Failing

  • Rattling cavitation noise and pressure fluctuation when upstream 20" Jumbo pre-filters choke
  • Water weeping from the mechanical shaft seal beneath the motor lantern bracket
  • Weak discharge head if 3-phase wiring drives the rotor in reverse rotation

Diagnostic Checklists If Something Goes Wrong

Step 1 · Verify 3-Phase Rotation Direction & Air Bleed

Is the pump spinning cleanly yet reaching only 40–60% of expected pressure and flow?

Watch the top cooling fan as power cuts off and match against the pump head arrow; bleed top vent plug completely.

Common Questions

What does TP mean in this Lyson pump model?

TP stands for Three-Phase (380–415V AC) industrial motor wiring—always verify rotation direction at commissioning.

Can this pump run continuously if raw feed stops?

Never—always wire a Low-Pressure Switch (LPS) ahead of pump suction into the starter contactor so dry water tanks shut the motor off instantly.

More in Multistage & Dosing Pumps

All Pumps →