Axtron UF Membrane 10 Inch (Hollow Fiber Membrane for 5 Stage UF System)

Axtron UF Membrane 10 Inch (Hollow Fiber Membrane for 5 Stage UF System)

10" inline 0.01–0.02 µm hollow-fiber UF cartridge blocking bacteria and colloids without electricity or drain water.

Compact 10" inline hollow-fiber membrane cartridge filtering water physically down to 0.01–0.02 microns on domestic line pressure alone. Blocks bacteria, cysts, and turbidity while passing natural dissolved minerals.

Application Scale & Replacement Verification

Scale: Domestic / HomeBrand: Axtron

Compare housing dimensions, port diameter, and membrane GPD capacity before ordering spares or requesting local dealer quotes. Verify System Fit in Water Planner →

Before You Install: Always flush upstream carbon cartridges before connecting the UF cartridge so loose carbon fines never block fiber openings.

Key Technical Specs

System SeriesAxtron
Architecture5-Stage Filtration
Standard Size10" × 2.5" Domestic
Application DutyDomestic / Home

Right Fit When

  • Non-electric 5-stage UF purifiers running on reasonably soft municipal tap water (<300 ppm TDS).
  • Setups requiring chemical-free bacterial reduction without UV bulbs or power outlets.

When To Skip or Double-Check

  • Skip UF if lowering dissolved TDS salts or hard water chalk scale is required—0.01 µm pores let all dissolved ions pass straight through.

Signs This Part Is Failing

  • Output drops drastically when colloidal silt blinds hollow fiber walls without backwashing
  • Cloudiness slips downstream if frozen/pressurized surges snap hollow fibers
  • High differential pressure builds between inlet and outlet ports

Diagnostic Checklists If Something Goes Wrong

Step 1 · Isolate fiber plugging vs upstream pre-filter choking

Did product output fall sharply even when feed pressure ahead of the UF module is >25–30 PSI?

Vent or disconnect the UF feed inlet briefly to confirm strong raw flow arrives at the module.

Common Questions

Can UF replace an RO membrane on salty borewell water?

No. UF filters bacteria and cloudiness down to 0.01–0.02 micron while leaving dissolved salt, arsenic, and hardness unchanged.

How long do hollow-fiber UF elements typically last?

12–18 months on clean pre-filtered tap feeds.