High Pressure Switch 6mm (Domestic RO Water Plant)

High Pressure Switch 6mm (Domestic RO Water Plant)

1/4" (6 mm) High-Pressure Switch (HPS) cutting booster power cleanly at 36–42 PSI once your RO tank fills.

Normally-closed 24V DC diaphragm micro-switch plumbed on the pure-water line between the membrane check valve and storage tank. Breaks power to both the booster pump and inlet solenoid the moment stored tank pressure climbs to ~40 PSI, resetting around ~22 PSI when you draw a few glasses.

Common Size / Rating Options
1/4" (6mm)3/8" (10mm)

Application Scale & Replacement Verification

Scale: Domestic / HomeBrand: Axtron

Compare housing dimensions, port diameter, and membrane GPD capacity before ordering spares or requesting local dealer quotes. Verify System Fit in Water Planner →

Before You Install: Plumb the HPS strictly AFTER the membrane one-way check valve—if placed before the check valve, tank pressure vanishes the instant the pump stops, causing violent machine-gun chattering.

Key Technical Specs

System SeriesAxtron
Port / Connection6mm
Application DutyDomestic / Home
Subcategory ClassSwitches Adapters And Spares

Right Fit When

  • All electric 24V/36V domestic and semi-commercial RO systems using pressurized bladder tanks.
  • 1/4" (6 mm) quick-connect permeate tubing downstream of a functional check valve.

When To Skip or Double-Check

  • Do NOT use an HPS alone on open atmospheric tanks with no pressure buildup—use an electric Float Switch instead.

Signs This Part Is Failing

  • Pump keeps running nonstop even when the storage tank is completely full and tight
  • Pump chatters ON-OFF-ON every 2 seconds near tank full pressure
  • Pump stays silent even when the tank is completely empty

Diagnostic Checklists If Something Goes Wrong

Step 1 · Pull one spade wire to test welded HPS contacts

Does the pump keep running non-stop even after shutting the storage tank ball valve for 10 seconds?

Shut the tank ball valve (pressure spikes above 40 PSI immediately); pull one wire off the HPS spade—if pump stops, HPS contacts failed closed.

Related System Troubleshooting Flows

Common Questions

Should an HPS be Normally Open or Normally Closed at 0 PSI?

Normally Closed (0 ohms at 0 PSI) so the pump runs while the tank is empty and opens the circuit once pressure reaches ~40 PSI.

Can you adjust the shutoff pressure on a 6mm HPS?

Yes, most include a tiny hex screw in the center—turn clockwise only 1/4 turn to raise cutoff slightly, or counter-clockwise to lower it.