High Pressure Switch 6mm (Domestic RO Water Plant)
1/4" (6 mm) High-Pressure Switch (HPS) cutting booster power cleanly at 36–42 PSI once your RO tank fills.
Normally-closed 24V DC diaphragm micro-switch plumbed on the pure-water line between the membrane check valve and storage tank. Breaks power to both the booster pump and inlet solenoid the moment stored tank pressure climbs to ~40 PSI, resetting around ~22 PSI when you draw a few glasses.
Application Scale & Replacement Verification
Compare housing dimensions, port diameter, and membrane GPD capacity before ordering spares or requesting local dealer quotes. Verify System Fit in Water Planner →
Key Technical Specs
| System Series | Axtron |
|---|---|
| Port / Connection | 6mm |
| Application Duty | Domestic / Home |
| Subcategory Class | Switches Adapters And Spares |
Right Fit When
- All electric 24V/36V domestic and semi-commercial RO systems using pressurized bladder tanks.
- 1/4" (6 mm) quick-connect permeate tubing downstream of a functional check valve.
When To Skip or Double-Check
- Do NOT use an HPS alone on open atmospheric tanks with no pressure buildup—use an electric Float Switch instead.
Signs This Part Is Failing
- Pump keeps running nonstop even when the storage tank is completely full and tight
- Pump chatters ON-OFF-ON every 2 seconds near tank full pressure
- Pump stays silent even when the tank is completely empty
Diagnostic Checklists If Something Goes Wrong
Does the pump keep running non-stop even after shutting the storage tank ball valve for 10 seconds?
Common Questions
Should an HPS be Normally Open or Normally Closed at 0 PSI?
Normally Closed (0 ohms at 0 PSI) so the pump runs while the tank is empty and opens the circuit once pressure reaches ~40 PSI.
Can you adjust the shutoff pressure on a 6mm HPS?
Yes, most include a tiny hex screw in the center—turn clockwise only 1/4 turn to raise cutoff slightly, or counter-clockwise to lower it.