Float Switch (Commercial Water Level Controller)

Float Switch (Commercial Water Level Controller)

Commercial cable float level switch automating atmospheric storage tank high-cutout and raw tank dry-run pump protection.

Sealed counterweight pendulum switch housing an internal micro-switch inside a chemical-resistant polypropylene float body. Automatically opens or closes pump/contactor circuits as tank water rises or falls inside commercial RO treated-water or raw-water storage tanks.

Common Size / Rating Options
1/4" (6mm)3/8" (10mm)

Application Scale & Replacement Verification

Scale: Commercial / IndustrialBrand: Axtron

Compare housing dimensions, port diameter, and membrane GPD capacity before ordering spares or requesting local dealer quotes. Verify System Fit in Water Planner →

Before You Install: Set the black counterweight collar 15–25 cm up the cable from the float body so water turbulence never whips the cable rapidly, and use waterproof heat-shrink/junction boxes above tank condensation.

Key Technical Specs

System SeriesAxtron
Application DutyCommercial / Industrial
Subcategory ClassSwitches Adapters And Spares
Operating EnvironmentRated Water Treatment Service

Right Fit When

  • Commercial 500L–20,000L atmospheric RO permeate tanks (Normally Closed: stops RO plant when tank fills).
  • Raw water feed tanks (Normally Open: stops transfer/multistage pumps when tank empties).

When To Skip or Double-Check

  • Always wire heavy >0.5HP 220V/3-phase pumps through a magnetic contactor relay rather than pulling full motor starting current through float micro-contacts.

Signs This Part Is Failing

  • Atmospheric storage tank overflows because float cable snagged on a riser pipe or contacts welded
  • RO plant refuses to start even though storage tank is half empty
  • Rapid pump start/stop bouncing from setting counterweight cord length too short

Diagnostic Checklists If Something Goes Wrong

Step 1 · Verify float travel & cable snag clearance

Does the tank overflow or stay locked off despite normal water level?

Open the top tank manway and lift/drop the tethered float bulb by hand while listening for the internal steel ball click.

Common Questions

Which wire colors control full-tank shutoff vs empty-tank protection?

Always test with a multimeter before wiring: one pair closes when hanging DOWN (for filling permeate tanks), and the other closes when floating UP (for emptying/sumps).

How do I stop rapid pump cycling in small storage tanks?

Give the counterweight a wider cable swing distance (25–35 cm) so the pump builds long run intervals between start and stop points.

More in Switches, Adapters & Seals

All Pumps →