Axtron 100 GPD Grand Forest RO Booster Pump (High Pressure Pump)

Axtron 100 GPD Grand Forest RO Booster Pump (High Pressure Pump)

24V DC diaphragm booster pump (100 GPD) building 70–95 PSI feed pressure across domestic RO membranes.

Domestic RO membranes stall and waste excessive drain water whenever tap pressure dips under 35 PSI. This quiet 3-chamber self-priming diaphragm pump (Axtron) lifts overhead tank or weak municipal supplies to 70–95 PSI so 1812 membranes hit full salt rejection. Pairs with a 24V 2A–2.5A DC power brick.

Common Size / Rating Options
100 GPD75 GPD24V DC

Application Scale & Replacement Verification

Scale: Domestic / HomeBrand: Axtron

Compare housing dimensions, port diameter, and membrane GPD capacity before ordering spares or requesting local dealer quotes. Verify System Fit in Water Planner →

Before You Install: Confirm power supply amperage before blame: a 100 GPD pump pulls ~1.8–2.2A at 80 PSI, so weak 1.2A adapters sag and cause clicking—also follow the embossed inlet-to-outlet arrow on the head.

Key Technical Specs

System SeriesAxtron
Rated Capacity100 GPD
Application DutyDomestic / Home
Nominal Supply Voltage24V DC (Requires Matching SMPS Adapter)

Right Fit When

  • Gravity roof-tank or low-pressure mains supplies (<35 PSI) feeding 100 GPD RO membranes.
  • Under-sink purifiers using 24V DC LPS/HPS series control wiring.

When To Skip or Double-Check

  • Never install a booster pump upstream of Stage 1 sediment filtration—grit immediately scores the 3-chamber diaphragm valves.

Signs This Part Is Failing

  • Motor vibrates yet outlet pressure stalls under 50 PSI on a test gauge
  • Water drips slowly from the weep hole underneath the diaphragm head
  • Pump stalls or stutters when an under-rated 24V adapter drops voltage under load

Diagnostic Checklists If Something Goes Wrong

Step 1 · Measure pump discharge PSI (Dead-Head / Running Test)

With clean Stage 1–3 filters feeding the pump, does a 0–150 PSI gauge on the pump outlet stall below 60 PSI?

Connect a glycerin pressure gauge directly to the pump outlet port for 5 seconds (do not dead-head longer than 5–10 seconds).

Related System Troubleshooting Flows

Common Questions

Can this 100 GPD booster pump draw water up from a ground sump?

Diaphragm booster pumps self-prime ~1–1.5 meters cleanly, though keeping a gravity-fed Stage 1 or flooded suction keeps diaphragm wear lowest.

Which way does water flow through the pump head?

Look for the raised arrow molded on the front black head plate—inlet receives water AFTER pre-filters, outlet pushes directly to the RO membrane housing cap.

More in Domestic Booster Pumps

All Pumps →