Germicidal UV-C 254nm Replacement Lamps, Quartz Sleeves & Seal Kits

Germicidal UV-C 254nm Replacement Lamps, Quartz Sleeves & Seal Kits

254nm germicidal UV-C replacement bulbs (6W–80W), optical quartz glass sleeves & gland seal O-rings.

Restores peak 254nm bacterial/viral inactivation output cleanly every 12 months (~9,000 hours). High-purity fused quartz sleeves isolate the fragile lamp from cold flowing water while transmitting >90% UV-C energy—paired with matching silicone/Viton gland O-rings.

Common Size / Rating Options
6W (GPH212)12W (GPH287)16W (GPH330)25W (GPH463)

Application Scale & Replacement Verification

Scale: Testing & MaintenanceBrand: Engineering Family

Compare housing dimensions, port diameter, and membrane GPD capacity before ordering spares or requesting local dealer quotes. Verify System Fit in Water Planner →

Before You Install: NEVER touch bare quartz glass sleeves or UV bulbs with bare skin—wipe with isopropyl alcohol using clean gloves so skin oils never bake dark black hot-spots onto the quartz.

Key Technical Specs

Engineering CategoryTesting & Maintenance · UV Replacement Lamps & Quartz Sleeves
Field Variants Tracked144 dimensional & pressure configurations
Industry StandardsNSF/ANSI 55 Compatible · Low-Pressure High-Output UV-C
Part4-Pin Single-End UV-C 254nm Lamp, 2-Pin Double-End UV-C Lamp, High-Output Amalgam UV-C Lamp, Open-Ended Fused Quartz Sleeve (+2 more)
Rating6W (GPH212), 12W (GPH287), 16W (GPH330), 25W (GPH463) (+4 more)
Diameter20mm Sleeve / 15mm Lamp, 23mm Standard Sleeve, 25mm-28mm High-Output Sleeve

Right Fit When

  • Annual scheduled maintenance on residential 6W–16W and commercial 40W–80W UV sterilizers.
  • Replacing scaled, hazed, or cracked quartz sleeves during annual lamp swaps.
  • Field aliases & trade names: UV Bulb, 254nm Germicidal Lamp, Quartz Glass Tube, Viqua S463RL/S330RL-Style.
  • Engineered to NSF/ANSI 55 Compatible, Low-Pressure High-Output UV-C criteria where applicable.

When To Skip or Double-Check

  • Check pin configuration (4-pin single-ended vs 2-pin double-ended), exact overall bulb length, and sleeve open/closed-end shape (open-both-ends vs domed closed-one-end) before unsealing glass components!

Signs This Part Is Failing

  • Ballast 365-day alarm
  • Burnt filament
  • Cloudy calcified quartz sleeve blocking UV rays

Diagnostic Checklists If Something Goes Wrong

Step 1 · Replace annual 12-month bulbs even while glowing blue

Did bacterial counts creep upward even though the UV lamp still emits faint visible blue light?

Check installation date—invisible 254nm germicidal intensity drops sharply past ~9,000 hours (~12 months).

Common Questions

Why must a quartz sleeve be cleaned every time you change a UV lamp?

Even a whisper-thin film of white hard water scale on the quartz glass cuts germicidal UV light penetration by 40–70%.

Are 40W Philips TUV and generic 33" 40W lamps interchangeable?

Check pin count (4-pin single-ended vs double-ended), overall pin-to-pin length (~843 mm), and ballast wattage—when pin pattern and wattage match, OEM-spec lamps interchange cleanly.

More in UV Sterilizers & Ozone

All Accessories →