Sub-Micron Pleated PES / PTFE / PP Sanitary Cartridge
Absolute Beta-5000 sub-micron (0.1–0.45 µm) PES/PTFE sanitary cartridge for final pharma, beverage & ultrapure protection.
Pleated asymmetric polyethersulfone (PES), hydrophilic PTFE, or micro-PP membrane sheets deliver validated >99.98% (Beta 5000) retention of bacteria, colloids, and sub-micron fines downstream of RO+EDI loops, tank vents, and beverage bottling headers.
Application Scale & Replacement Verification
Compare housing dimensions, port diameter, and membrane GPD capacity before ordering spares or requesting local dealer quotes. Verify System Fit in Water Planner →
Key Technical Specs
| Engineering Category | Industrial RO · Sub-Micron Polishing & Sterilizing Pre-Filters |
|---|---|
| Field Variants Tracked | 1,024 dimensional & pressure configurations |
| Industry Standards | FDA 21 CFR 177 · USP Class VI · ISO 9001 |
| Size | 10" Sanitary (2.7"x10"), 20" Sanitary (2.7"x20"), 30" Sanitary (2.7"x30"), 40" Sanitary (2.7"x40") |
| Micron | 0.1 micron, 0.2 micron, 0.45 micron, 1 micron |
| Media | Hydrophilic PES Membrane, Absolute Pleated Polypropylene, Hydrophobic PTFE Vent/Liquid, Nylon 6,6 Membrane |
| Endcap | 222 O-Ring / Fin, 222 O-Ring / Flat Cap, 226 O-Ring / Fin, DOE |
Right Fit When
- Pharmaceutical PW/WFI distribution, food/beverage bottling, and 18.2 MΩ·cm lab ultrapure loops.
- 222/Flat, 222/Fin, or 226/Fin O-ring locking sanitary stainless housings.
- Field aliases & trade names: 0.22 Micron Sterile Filter, PES Pleated Cartridge, Pharma Polishing Filter, Bacteria Retention Cartridge.
- Engineered to FDA 21 CFR 177, USP Class VI, ISO 9001 criteria where applicable.
When To Skip or Double-Check
- NEVER place an expensive absolute 0.2 µm PES membrane directly on raw tap/well water without coarse 1–5 µm pre-filtration—colloids blind it in hours.
Signs This Part Is Failing
- Rapid transmembrane pressure spike across polish stage
- Bubble-point integrity failure
- Elevated microbial CFU counts in purified loop
Diagnostic Checklists If Something Goes Wrong
Has transmembrane Delta-P climbed above 20–25 PSI (or flow dropped noticeably)?
Common Questions
What is the difference between Nominal and Absolute Beta-5000 ratings?
Nominal filters capture ~85% of rated particle size while Absolute Beta-5000 captures 99.98%, essential for pharmaceutical and beverage sterility.
222 vs 226 O-ring end caps—are they interchangeable?
No—Code 7 (226) adds two twist-lock bayonet locking ears to resist reverse back-pressure pulses and will not lock into Code 3 (222) pockets.