Sub-Micron Pleated PES / PTFE / PP Sanitary Cartridge

Sub-Micron Pleated PES / PTFE / PP Sanitary Cartridge

Absolute Beta-5000 sub-micron (0.1–0.45 µm) PES/PTFE sanitary cartridge for final pharma, beverage & ultrapure protection.

Pleated asymmetric polyethersulfone (PES), hydrophilic PTFE, or micro-PP membrane sheets deliver validated >99.98% (Beta 5000) retention of bacteria, colloids, and sub-micron fines downstream of RO+EDI loops, tank vents, and beverage bottling headers.

Common Size / Rating Options
0.1 µm0.2 µm0.45 µm1 µm

Application Scale & Replacement Verification

Scale: Industrial ROBrand: Engineering Family

Compare housing dimensions, port diameter, and membrane GPD capacity before ordering spares or requesting local dealer quotes. Verify System Fit in Water Planner →

Before You Install: Verify exact locking bayonet style (Code 3/222 vs Code 7/226 dual-bayonet fins) and wet EPDM/Silicone/Viton O-rings purely with pure RO water—never grease pharma sanitary O-rings with hydrocarbon oils.

Key Technical Specs

Engineering CategoryIndustrial RO · Sub-Micron Polishing & Sterilizing Pre-Filters
Field Variants Tracked1,024 dimensional & pressure configurations
Industry StandardsFDA 21 CFR 177 · USP Class VI · ISO 9001
Size10" Sanitary (2.7"x10"), 20" Sanitary (2.7"x20"), 30" Sanitary (2.7"x30"), 40" Sanitary (2.7"x40")
Micron0.1 micron, 0.2 micron, 0.45 micron, 1 micron
MediaHydrophilic PES Membrane, Absolute Pleated Polypropylene, Hydrophobic PTFE Vent/Liquid, Nylon 6,6 Membrane
Endcap222 O-Ring / Fin, 222 O-Ring / Flat Cap, 226 O-Ring / Fin, DOE

Right Fit When

  • Pharmaceutical PW/WFI distribution, food/beverage bottling, and 18.2 MΩ·cm lab ultrapure loops.
  • 222/Flat, 222/Fin, or 226/Fin O-ring locking sanitary stainless housings.
  • Field aliases & trade names: 0.22 Micron Sterile Filter, PES Pleated Cartridge, Pharma Polishing Filter, Bacteria Retention Cartridge.
  • Engineered to FDA 21 CFR 177, USP Class VI, ISO 9001 criteria where applicable.

When To Skip or Double-Check

  • NEVER place an expensive absolute 0.2 µm PES membrane directly on raw tap/well water without coarse 1–5 µm pre-filtration—colloids blind it in hours.

Signs This Part Is Failing

  • Rapid transmembrane pressure spike across polish stage
  • Bubble-point integrity failure
  • Elevated microbial CFU counts in purified loop

Diagnostic Checklists If Something Goes Wrong

Step 1 · Track differential pressure across sanitary housing

Has transmembrane Delta-P climbed above 20–25 PSI (or flow dropped noticeably)?

Compare inlet vs outlet sanitary diaphragm pressure gauges across the housing.

Common Questions

What is the difference between Nominal and Absolute Beta-5000 ratings?

Nominal filters capture ~85% of rated particle size while Absolute Beta-5000 captures 99.98%, essential for pharmaceutical and beverage sterility.

222 vs 226 O-ring end caps—are they interchangeable?

No—Code 7 (226) adds two twist-lock bayonet locking ears to resist reverse back-pressure pulses and will not lock into Code 3 (222) pockets.

More in Service Packs & Specialty

All Filters →