Seawater Desalination (SWRO) High-Rejection RO Membrane Elements
High-pressure 800–1,200 PSI SWRO desalination elements rejecting 99.7%+ NaCl and boron from seawater.
Engineered with dense cross-linked polyamide skins and heavy-duty fiberglass shells to overcome 35,000–45,000 ppm seawater osmotic pressure at 800–1,200 PSI (55–83 bar)—delivering safe drinking water (<500 ppm) and strict WHO boron rejection for marine watermakers and coastal desalination plants.
Application Scale & Replacement Verification
Compare housing dimensions, port diameter, and membrane GPD capacity before ordering spares or requesting local dealer quotes. Verify System Fit in Water Planner →
Key Technical Specs
| Engineering Category | Industrial RO · Seawater Desalination (SWRO) Membranes |
|---|---|
| Field Variants Tracked | 256 dimensional & pressure configurations |
| Industry Standards | NSF/ANSI 61 · ISO 9001 · Marine/Desalination Spec |
| Size | 2521, 2540, 4021, 4040 (+1 more) |
| Series | SW30HR High-Rejection (99.8% NaCl), SW30XLE Low-Energy Seawater, SWC5/TM820 High-Boron-Rejection, Marine Watermaker Compact SW |
| Area | 14 sq ft, 28 sq ft, 40 sq ft, 85 sq ft (+3 more) |
| Wrap | FRP Fiberglass Hard-Shell, Tape-Wrapped Marine |
Right Fit When
- Marine boat watermakers (2521/2540/4021/4040) and coastal municipal/resort SWRO skids (4040/8040).
- Systems driven by axial-piston or duplex high-pressure SWRO pumps with FRP 1,000–1,200 PSI pressure vessels.
- Field aliases & trade names: SW30 Membrane, SW30HRLE-400, Hydranautics SWC5/SWC6, Toray TM820.
- Engineered to NSF/ANSI 61, ISO 9001, Marine/Desalination Spec criteria where applicable.
When To Skip or Double-Check
- NEVER run SWRO elements in low-pressure 300 PSI brackish vessels or on weak centrifugal pumps—seawater osmotic pressure alone exceeds ~350–400 PSI before any water permeates!
Signs This Part Is Failing
- Permeate TDS creeping >500 ppm
- Boron exceedance
- Severe calcium sulfate
Diagnostic Checklists If Something Goes Wrong
Is feed pressure climbing steeply above 950–1,050 PSI to maintain rated permeate flow?
Common Questions
Why do seawater RO systems need 800–1,000 PSI while brackish needs 150–225 PSI?
Natural osmotic pressure of 35,000 ppm seawater is roughly ~370 PSI alone; overcoming that osmotic barrier and forcing pure water through tight SWRO sheets takes 800–1,000+ PSI.
Can you use SS304 pressure vessels or pumps on SWRO brine?
Never—chloride levels in seawater pit SS304 and even SS316 rapidly; use 1,000–1,200 PSI FRP vessels and Duplex/Super-Duplex stainless or ceramic axial-piston pumps.