UPVC Y-Strainers, Basket Strainers & Chemical Tank Foot Valves

UPVC Y-Strainers, Basket Strainers & Chemical Tank Foot Valves

UPVC Y-strainers, basket screens & spring foot valves guarding dosing/feed pumps from debris & lost prime.

Clear-bowl UPVC Y-strainers and basket screens catch pipe rust, gravel, and gasket shreds before they ruin expensive multiport heads, rotary vane pumps, or dosing check balls—while vertical spring-loaded PVC foot valves hold suction water column prime inside ground/chemical tanks.

Common Size / Rating Options
1/2" Socket/NPT3/4" Socket/NPT1" Socket/NPT1.5" Socket/NPT

Application Scale & Replacement Verification

Scale: Fittings & ValvesBrand: Engineering Family

Compare housing dimensions, port diameter, and membrane GPD capacity before ordering spares or requesting local dealer quotes. Verify System Fit in Water Planner →

Before You Install: Mount spring-loaded PVC foot valves ~10–15 cm ABOVE the very bottom floor of raw/chemical tanks so settled mud and chemical sludge never suck straight into the suction screen.

Key Technical Specs

Engineering CategoryFittings & Valves · Strainers & Foot Valves
Field Variants Tracked42 dimensional & pressure configurations
Industry StandardsNSF/ANSI 61 · ASTM D1784
TypeTrue-Union Clear UPVC Y-Strainer (20-40 Mesh), Pump Suction Weighted Foot Valve + Screen, Chemical Dosing Micro-Foot Valve (Ceramic Weight)
Size1/4" Tubing (Dosing), 3/8" Tubing (Dosing), 1/2" Socket/NPT, 3/4" Socket/NPT (+3 more)
SealEPDM Seal, Viton FKM Seal

Right Fit When

  • Raw water transfer suction lines (foot valves) and chemical dosing/feed headers (Y-strainers).
  • 1/2" to 4" Schedule 80 UPVC socket or threaded commercial RO manifolds.
  • Field aliases & trade names: Y-Strainer, Pump Suction Foot Valve, Chemical Dosing Foot Valve, Clear Screen Strainer.
  • Engineered to NSF/ANSI 61, ASTM D1784 criteria where applicable.

When To Skip or Double-Check

  • Keep clear PVC Y-strainer bowls shaded indoors (UV sun weakens clear PVC), and mount Y-strainers strictly with the screen leg pointing DOWNWARD so debris drops out of flow instead of falling back up pipe!

Signs This Part Is Failing

  • Pump losing prime overnight (leaking foot valve seal)
  • Starved pump suction from debris-clogged Y-strainer basket

Diagnostic Checklists If Something Goes Wrong

Step 1 · Stop transfer pump losing prime overnight (Foot Valve)

Does the raw feed pump run dry every morning until re-primed with a bucket?

Pull the suction pipe out of the raw tank and pour water down from top: water draining straight out the bottom proves foot valve failure.

Common Questions

Swing/Flapper foot valve vs Spring-loaded foot valve—which seals tighter?

Always pick spring-loaded poppet foot valves on suction pumps—vertical gravity flappers often hang open slightly on low-head pipes and drop prime overnight.

Can clear PVC Y-strainers go on the high-pressure outlet of an RO pump?

Never! Clear PVC strainers are for low-pressure (<80–120 PSI) suction and feed lines; high-pressure pump outlets require SS304/316 housings.

More in LLDPE Tubing & Strainers

All Valves & Fittings →