NR Socket 6mm (PVC Connector)

NR Socket 6mm (PVC Connector)

One-way 6mm non-return check valve locking pressurized RO tank water from leaking backward down the drain.

Mounts directly on the center pure-water outlet of the RO membrane housing so forward permeate enters the storage tank with ~1 PSI cracking resistance while locking completely shut whenever the pump stops—preventing nonstop drain waste and pump short-cycling.

Application Scale & Replacement Verification

Scale: Domestic / HomeBrand: Axtron

Compare housing dimensions, port diameter, and membrane GPD capacity before ordering spares or requesting local dealer quotes. Verify System Fit in Water Planner →

Before You Install: Do the 2-second mouth blow test before fitting: blow gently through the exit end backward—if ANY air sneaks back through, the spring O-ring is faulty; always point the embossed arrow AWAY from the membrane.

Key Technical Specs

System SeriesAxtron
Port / Connection6mm
Application DutyDomestic / Home
Working Pressure Range15–120 PSI System Line Control

Right Fit When

  • Domestic 1/4" (6 mm) RO lines fixing continuous waste-drain leaks or rapid HPS pump chatter.
  • Membrane housing center permeate port.

When To Skip or Double-Check

  • Verify thread vs push-fit connection (1/8" male NPT threads directly into 1812 shell center port vs 6mm tube-to-tube inline) before ordering.

Signs This Part Is Failing

  • Waste water runs continuously when the pump is off until you shut the storage tank ball valve
  • Booster pump clicks ON and OFF every 3–5 seconds when the tank is nearly full
  • Zero pure water reaches the tank if installed backward

Diagnostic Checklists If Something Goes Wrong

Step 1 · Close tank ball valve to prove check-valve backflow

Does the nonstop sink drain trickle stop within 60 seconds ONLY when you close the quarter-turn tank valve?

Close the storage tank valve while power is unplugged and watch the waste line.

Related System Troubleshooting Flows

Common Questions

Where does the membrane check valve go—center port or side port?

Strictly on the CENTER pure-water port at the bottom of the membrane shell (the offset port is the brine waste line for the flow restrictor).

How does a broken check valve make the pump cycle nonstop?

Tank water bleeds backward out the drain, dropping HPS pressure below 25 PSI every few seconds and re-triggering the pump.