Dedicated RO Membrane Housing Port Elbows, Tees & Integrated Check Elbows

Dedicated RO Membrane Housing Port Elbows, Tees & Integrated Check Elbows

1/8" NPT & 1/4"/3/8" membrane housing elbows, tees & integrated permeate check elbows.

Purpose-built threaded male elbows and integrated one-way check fittings threading directly into domestic 1812/2012/3012 RO membrane shell ports. Prevents mistaking the critical pure-port check elbow for an ordinary open brine elbow—stopping continuous drain leaks cleanly.

Common Size / Rating Options
Single10-Pack

Application Scale & Replacement Verification

Scale: Fittings & ValvesBrand: Engineering Family

Compare housing dimensions, port diameter, and membrane GPD capacity before ordering spares or requesting local dealer quotes. Verify System Fit in Water Planner →

Before You Install: Remember the 1812 port map: Cap End = 1 Feed Inlet; Bottom Tail End = Center socket is Pure Permeate (Check Elbow ONLY!) + Offset port is Brine Drain (leads to Flow Restrictor).

Key Technical Specs

Engineering CategoryFittings & Valves · Membrane Housing Port Fittings
Field Variants Tracked81 dimensional & pressure configurations
Industry StandardsNSF/ANSI 58 · NSF/ANSI 61
Port FunctionFeed Inlet Elbow (No Check), Concentrate/Brine Outlet Elbow (No Check), Permeate Outlet Check-Valve Elbow (NRV Built-In)
Thread1/8" Male NPTF (1812/2012), 1/4" Male NPTF (3012/3013), 3/8" Male NPTF (High-Flow)
Tube1/4" QC Push-Fit, 3/8" QC Push-Fit, 1/4" Jaco Compression
PackSingle, 3-Port Complete Housing Kit, 10-Pack

Right Fit When

  • Replacing cracked 1/8" NPT cap feed elbows, pure-port check elbows, and offset brine elbows.
  • 1/4" (6mm) and 3/8" (10mm) quick-connect push-fit membrane assemblies.
  • Field aliases & trade names: Membrane Elbow 1/8 NPT, Permeate Check Elbow, Brine Reject Elbow, Housing Cap Fitting.
  • Engineered to NSF/ANSI 58, NSF/ANSI 61 criteria where applicable.

When To Skip or Double-Check

  • NEVER put a plain open elbow on the center pure port or put a check elbow onto the offset brine waste port—mixing them up breaks cutoff or halts drain flow completely!

Signs This Part Is Failing

  • Leaking raw water from cracked 1/8" plastic threads
  • Reverse flow into permeate port if plain elbow is mistakenly installed instead of check-elbow

Diagnostic Checklists If Something Goes Wrong

Step 1 · Blow-test center check elbow against drain waste

Does waste water keep dripping after the pump shuts off unless you close the tank valve?

Remove the CENTER bottom elbow and blow gently backward through the push-fit end.

Common Questions

How can I visually tell a Check Elbow from a plain Membrane Elbow?

Check elbows usually look slightly thicker/longer around the throat with an embossed arrow pointing out—and you CANNOT blow air backward through the push-fit tube hole.

Do I wrap PTFE tape on O-ring boss membrane elbows?

If the elbow already features a captive rubber O-ring against a flat flange collar, NO PTFE tape is needed—only tapered 1/8" NPT threads require PTFE tape.

More in Push-Fit Fittings

All Valves & Fittings →