FRP Mineral / Softener Pressure Tanks, Atmospheric Tanks & Riser Distributors
FRP fiberglass mineral vessels (8×18 to 36×72), brine salt tanks & riser/lateral underdrains.
Seamless food-grade HDPE inner liners wrapped in filament-wound fiberglass holding bulk softening resin, activated carbon, multimedia sand, or arsenic/iron adsorbents under up to 150 PSI—paired with brine regeneration tanks (with safety float wells) and slotted riser/lateral distributors.
Application Scale & Replacement Verification
Compare housing dimensions, port diameter, and membrane GPD capacity before ordering spares or requesting local dealer quotes. Verify System Fit in Water Planner →
Key Technical Specs
| Engineering Category | Whole House · FRP Mineral Vessels, Atmospheric & Brine Tanks |
|---|---|
| Field Variants Tracked | 396 dimensional & pressure configurations |
| Industry Standards | NSF/ANSI 44 · NSF/ANSI 61 · WQA Gold Seal |
| Dimension | 8"x44" (0.75 cu ft), 9"x48" (1.0 cu ft), 10"x54" (1.5 cu ft), 12"x52" (2.0 cu ft) (+7 more) |
| Opening | 2.5" NPSM Top Opening, 4" 8-UN Top Opening, 6" Top & Bottom Flanged |
| Component | FRP Tank + Base, Tank + Riser Tube + Basket/Hub-Lateral Kit, Complete Brine Tank with Salt Grid & Safety Float, Atmospheric LLDPE Permeate/Raw Water Tank |
| Color | Blue, Natural Almond, Black |
Right Fit When
- Whole-house softeners, commercial RO pre-treatment carbon/multimedia trains, and brine regeneration stations.
- 2.5" threaded top openings (up to 13×54) and 4" top/bottom commercial vessels (16×65 to 36×72).
- Field aliases & trade names: FRP Vessel 10x54, 13x54 Resin Tank, Salt Brine Drum, Hub & Lateral Distributor.
- Engineered to NSF/ANSI 44, NSF/ANSI 61, WQA Gold Seal criteria where applicable.
When To Skip or Double-Check
- Install vacuum-breaker safety valves on tall >16" FRP vessels fed by strong booster pumps—negative suction drain siphons collapse internal HDPE tank liners permanently.
Signs This Part Is Failing
- Resin beads flooding plumbing (cracked bottom basket/lateral)
- Briny taste after regen (stuck brine float)
- Weeping top-thread neck
Diagnostic Checklists If Something Goes Wrong
Are amber resin beads, carbon chips, or sand appearing in downstream filters or fixtures?
Common Questions
How much media fits cleanly in an 8×44, 10×54, or 13×54 FRP tank?
Allowing 35–40% backwash headspace: 8×44 holds ~0.75 cu ft, 10×54 holds ~1.5 cu ft, and 13×54 holds ~2.5 cu ft of active resin or carbon.
Why does the brine tank still have water sitting at the bottom?
That is completely normal! Softener control valves refill the brine tank with fresh water at the end of regeneration so salt dissolves ready for the NEXT cycle.