Axtron 400 GPD RO Plant (Single Filmtec Membrane) (Complete 5 Stage Reverse Osmosis System)

Axtron 400 GPD RO Plant (Single Filmtec Membrane) (Complete 5 Stage Reverse Osmosis System)

400 GPD (~63 L/hr) semi-commercial skid built with a single high-flow 400 GPD element.

Delivers ~63 L/hr continuous output using heavy-duty pre-filtration and high-flow 3012/3013 single-element architecture built for commercial draw far beyond household 10" units.

Common Size / Rating Options
400 GPD200 GPD600 GPD800 GPD

Application Scale & Replacement Verification

Scale: Semi-CommercialBrand: Axtron

Compare housing dimensions, port diameter, and membrane GPD capacity before ordering spares or requesting local dealer quotes. Verify System Fit in Water Planner →

Before You Install: Plumb incoming water with full 3/8" (10 mm) LLDPE tubing all the way to the pump suction port—narrow 1/4" lines cavitate 300–1200 GPD diaphragm pumps and trigger LPS chatter.

Key Technical Specs

System SeriesAxtron
Architecture5-Stage Filtration
Rated Capacity400 GPD
Application DutySemi-Commercial

Right Fit When

  • Cafes, espresso bars, dental clinics, and offices drawing 150–600 L/day.
  • Feedlines paired with 11G or 20G pressurized bladder tanks or float-controlled atmospheric reservoirs.

When To Skip or Double-Check

  • Skip diaphragm-pump skids if facility demand exceeds 2,000 L/day or runs 12+ continuous hours—step up to a stainless multistage 4040 commercial plant so diaphragm heads do not overheat.

Signs This Part Is Failing

  • Hourly permeate flow drops below 70% of rated LPH even with fresh pre-filters
  • High-flow booster heads chatter via LPS or run overly hot under extended draw
  • Product TDS climbs past 10% of raw water reading or espresso/ice equipment shows scale

Diagnostic Checklists If Something Goes Wrong

Step 1 · Isolate suction starvation across 20" pre-filters

Are booster pumps vibrating loudly, pulsing ON/OFF, or losing pressure during peak draw?

Crack the 3/8" tube feeding the pump manifold: weak flow indicates plugged 20" Slim sediment/CTO cartridges or undersized 1/4" supply piping.

Common Questions

Can this semi-commercial RO feed an atmospheric tank or pressurized tank?

Both—use a tank float switch wired to the controller for atmospheric tanks, or an 11G/20G bladder tank with an HPS cutoff switch for pressurized espresso/tap lines.

Why does a 20" Slim pre-filter bank matter here?

High-flow 300–1200 GPD pumps pull 3–6× more feed volume than domestic units; 10" cartridges blind within days while 20" Slim housings sustain clean suction.