AXFLOW BW8040 RO Membrane for Commercial 1000 LPH 1 Ton Plant
8040 BW high-rejection brackish element (~10,500 GPD / ~1,650 L/hr) engineered for 150–225 PSI industrial RO vessels.
Commercial fiberglass-wrapped polyamide RO element operating inside 8040 FRP or SS304 pressure vessels (~10,500 GPD / ~1,650 L/hr per element). Built with rigid fiberglass outer wrap and pH 1–13 CIP tolerance for continuous bottling, boiler makeup, and industrial plant shifts.
Application Scale & Replacement Verification
Compare housing dimensions, port diameter, and membrane GPD capacity before ordering spares or requesting local dealer quotes. Verify System Fit in Water Planner →
Key Technical Specs
| Manufacturer / Series | AXFLOW |
|---|---|
| Rated Output | 1000 LPH |
| Application Duty | Commercial / Industrial |
| Element Construction | Spiral-Wound Polyamide Thin-Film Composite |
Right Fit When
- 8040 multi-element or single-element FRP/SS vessels operating at 150–225 PSI with upstream 5 µm Jumbo/multi-round guard filtration.
- Industrial bottling, pharma pre-EDI, and brackish borehole skids up to 5,000–10,000 ppm TDS.
When To Skip or Double-Check
- Never feed >0.0 ppm free chlorine or high hardness without activated carbon / SMBS dechlorination and active antiscalant dosing—even a 1-hour chlorine spike ruins a 8040 element permanently.
- Confirm vessel diameter (8-inch ID) and permeate interconnector style before pulling end caps.
Signs This Part Is Failing
- Differential pressure (Delta-P) across the 8040 pressure vessel climbs >15 PSI above baseline
- Permeate conductivity spikes on a vessel port from pinched interconnector O-rings or chlorine oxidation
- Normalized permeate LPH drops 15%+, signaling scale or biofouling requiring chemical CIP cleaning
Diagnostic Checklists If Something Goes Wrong
Has Feed Header PSI minus Concentrate Header PSI risen >15 PSI per element (or >15% above commissioning day)?
Common Questions
How do I know if a 8040 membrane needs CIP cleaning vs replacement?
If permeate flow dropped alongside rising Delta-P (fouling/scaling), CIP chemical cleaning usually restores flux. If flow rose abnormally while TDS spiked (chlorine burn or telescoping), the sheet is damaged and needs replacement.
Which direction does the brine seal face inside a 4040/8040 housing?
Always mount the U-cup brine seal on the upstream (feed) side of each element with the open groove/lip facing into the incoming feed flow so water pressure flares it tight against the vessel wall.