4-Way Hydraulic Auto Shut-Off Valves (ASOV) & Electronic Solenoid Valves
4-way hydraulic ASOVs & 24V/220V electric solenoid shutoff valves stopping drain waste when storage tanks fill.
Automates feed water shutoff so RO systems do not run waste water down the drain 24/7. Non-electric purifiers use 4-way hydraulic Auto Shut-Off Valves (pinching feed at ~60% tank pressure); pumped skids use Normally-Closed 24V/220V electric Solenoid Valves wired in parallel with the booster pump.
Application Scale & Replacement Verification
Compare housing dimensions, port diameter, and membrane GPD capacity before ordering spares or requesting local dealer quotes. Verify System Fit in Water Planner →
Key Technical Specs
| Engineering Category | Fittings & Valves · Auto Shut-Off & Solenoid Valves |
|---|---|
| Field Variants Tracked | 630 dimensional & pressure configurations |
| Industry Standards | NSF/ANSI 58 · CE · UL Coil |
| Valve Type | 4-Way Hydraulic Auto Shut-Off Valve (ASOV 60% Ratio), 4-Way Hydraulic ASOV High-Efficiency (90% Ratio for Permeate Pump), Normally-Closed (NC) Inlet Solenoid Valve, Auto-Flush Bypass Solenoid Valve (Parallel to Restrictor) (+1 more) |
| Voltage | Non-Electric Hydraulic, 12VDC, 24VDC, 24VAC (+2 more) |
| Port | 1/4" QC Push-Fit, 3/8" QC Push-Fit, 1/4" Jaco Compression, 1/4" FNPT (+3 more) |
| Seal | EPDM Diaphragm/Seal, Viton FKM Seal, PTFE High-Temp/High-Pressure |
Right Fit When
- Electric pumped ROs (24V DC / 220V AC NC inlet solenoids & auto-flush solenoids).
- Non-electric RO setups >40 PSI mains (4-way hydraulic ASOVs with matched check valves).
- Field aliases & trade names: 4-Way Valve, ASOV, Electric Inlet Solenoid, Auto-Flush Solenoid Valve.
- Engineered to NSF/ANSI 58, CE, UL Coil criteria where applicable.
When To Skip or Double-Check
- Check valve type strictly: inlet shutoff solenoids stay Normally Closed (NC) at 0V; never wire an under-rated domestic plastic solenoid directly into 220V commercial mains without matching coil voltage.
Signs This Part Is Failing
- Waste drain water never stops running (torn ASOV diaphragm
- Stuck solenoid plunger)
- Zero water entering membrane
Diagnostic Checklists If Something Goes Wrong
Does waste water keep trickling continuously even after unplugging the RO power brick for 2 minutes?
Common Questions
Should a pumped electric RO use BOTH a 4-way ASOV and a 24V Solenoid?
Usually no—a 24V Solenoid wired in parallel with the booster pump + HPS shuts off cleanly with zero pressure restriction, whereas adding an old ASOV adds an extra failure point.
Why does a 24V solenoid fail to shut off on high city water pressure (>90 PSI)?
Excessive incoming line pressure can overpower small plastic solenoid springs—install a 60 PSI PRV upstream.