4-Way Hydraulic Auto Shut-Off Valves (ASOV) & Electronic Solenoid Valves

4-Way Hydraulic Auto Shut-Off Valves (ASOV) & Electronic Solenoid Valves

4-way hydraulic ASOVs & 24V/220V electric solenoid shutoff valves stopping drain waste when storage tanks fill.

Automates feed water shutoff so RO systems do not run waste water down the drain 24/7. Non-electric purifiers use 4-way hydraulic Auto Shut-Off Valves (pinching feed at ~60% tank pressure); pumped skids use Normally-Closed 24V/220V electric Solenoid Valves wired in parallel with the booster pump.

Common Size / Rating Options
12VDC24VDC24VAC110VAC

Application Scale & Replacement Verification

Scale: Fittings & ValvesBrand: Engineering Family

Compare housing dimensions, port diameter, and membrane GPD capacity before ordering spares or requesting local dealer quotes. Verify System Fit in Water Planner →

Before You Install: Install an inlet solenoid valve AFTER Stage 1 sediment filtration (never before!) so raw sand grit cannot wedge inside the rubber diaphragm seat and cause permanent nonstop drain leaks.

Key Technical Specs

Engineering CategoryFittings & Valves · Auto Shut-Off & Solenoid Valves
Field Variants Tracked630 dimensional & pressure configurations
Industry StandardsNSF/ANSI 58 · CE · UL Coil
Valve Type4-Way Hydraulic Auto Shut-Off Valve (ASOV 60% Ratio), 4-Way Hydraulic ASOV High-Efficiency (90% Ratio for Permeate Pump), Normally-Closed (NC) Inlet Solenoid Valve, Auto-Flush Bypass Solenoid Valve (Parallel to Restrictor) (+1 more)
VoltageNon-Electric Hydraulic, 12VDC, 24VDC, 24VAC (+2 more)
Port1/4" QC Push-Fit, 3/8" QC Push-Fit, 1/4" Jaco Compression, 1/4" FNPT (+3 more)
SealEPDM Diaphragm/Seal, Viton FKM Seal, PTFE High-Temp/High-Pressure

Right Fit When

  • Electric pumped ROs (24V DC / 220V AC NC inlet solenoids & auto-flush solenoids).
  • Non-electric RO setups >40 PSI mains (4-way hydraulic ASOVs with matched check valves).
  • Field aliases & trade names: 4-Way Valve, ASOV, Electric Inlet Solenoid, Auto-Flush Solenoid Valve.
  • Engineered to NSF/ANSI 58, CE, UL Coil criteria where applicable.

When To Skip or Double-Check

  • Check valve type strictly: inlet shutoff solenoids stay Normally Closed (NC) at 0V; never wire an under-rated domestic plastic solenoid directly into 220V commercial mains without matching coil voltage.

Signs This Part Is Failing

  • Waste drain water never stops running (torn ASOV diaphragm
  • Stuck solenoid plunger)
  • Zero water entering membrane

Diagnostic Checklists If Something Goes Wrong

Step 1 · Unplug power to catch stuck electric solenoid seats

Does waste water keep trickling continuously even after unplugging the RO power brick for 2 minutes?

Unplug wall power completely and watch the black drain line inside a clear cup.

Common Questions

Should a pumped electric RO use BOTH a 4-way ASOV and a 24V Solenoid?

Usually no—a 24V Solenoid wired in parallel with the booster pump + HPS shuts off cleanly with zero pressure restriction, whereas adding an old ASOV adds an extra failure point.

Why does a 24V solenoid fail to shut off on high city water pressure (>90 PSI)?

Excessive incoming line pressure can overpower small plastic solenoid springs—install a 60 PSI PRV upstream.

More in Check, Solenoid & ASOV