150 PSI Commercial Water Pressure Gauge (& Accurate)

150 PSI Commercial Water Pressure Gauge (& Accurate)

150 PSI glycerin-filled commercial stainless pressure gauge (Bottom 1/4" NPT) monitoring pre-filter Delta-P.

Liquid glycerin damping protects the internal brass Bourdon spring and gears from intense multistage pump vibration and pressure pulsations. Lets operators read pre-filter inlets/outlets, FRP backwash headers, and 20" Jumbo differential tracking (0–100 PSI) accurately without pointer chatter.

Application Scale & Replacement Verification

Scale: Commercial / IndustrialBrand: Axtron

Compare housing dimensions, port diameter, and membrane GPD capacity before ordering spares or requesting local dealer quotes. Verify System Fit in Water Planner →

Before You Install: Use a wrench strictly on the square brass hex flat—NEVER twist the round stainless case by hand or pipe pliers, which snaps the internal capillary weld—and snip or unseal the tiny top rubber vent plug after mounting vertically so internal thermal pressure equalizes.

Key Technical Specs

System SeriesAxtron
Pressure Range150 PSI max scale
Application DutyCommercial / Industrial
Damping / Wetted DesignGlycerin-Filled Brass or SS316 / Acrylic Float

Right Fit When

  • Raw feed headers, before/after 20" Jumbo guard filters (spot >15 PSI Delta-P), and FRP media tanks.
  • Commercial skid panels using standard 1/4" NPT brass fittings.

When To Skip or Double-Check

  • NEVER install a 150 PSI gauge on high-pressure brackish 4040/8040 pump discharges (160–250 PSI)—over-pressurizing bends the Bourdon tube past zero permanently; step up to a 350 PSI gauge.

Signs This Part Is Failing

  • Needle sticks well above 0 PSI even when the RO skid is shut off and depressurized
  • Pointer vibrates wildly like a blur (glycerin leaked out or severe pump cavitation)
  • Water beads slowly at the 1/4" brass thread root

Diagnostic Checklists If Something Goes Wrong

Step 1 · Check zero-rest accuracy when plant is shut off

Does the pointer stay stuck at 15–40 PSI even with all valves open at atmospheric zero pressure?

Depressurize the header completely and look straight onto the dial.

Common Questions

Why does a glycerin-filled gauge show a small air bubble at the top?

That intentional expansion bubble prevents thermal expansion from blowing out the front lens—keep the top bezel upright during service.

Should I use a 150 PSI or 350 PSI gauge on a 4040 commercial membrane housing?

Use 150 PSI gauges before and after the 20" Jumbo pre-filters, and 350 PSI gauges on the high-pressure pump discharge and concentrate outlet.