10 Gram Ozone Generator Analog (DNA-10G) for 6 to 10 Ton Water Filling Plants

10 Gram Ozone Generator Analog (DNA-10G) for 6 to 10 Ton Water Filling Plants

10 g/hr corona-discharge ozone generator sanitizing commercial RO storage tanks and bottling lines chemically-free.

Splits oxygen molecules via controlled high-voltage corona discharge to inject 10 g/hr of O3 gas through a venturi or diffuser stone into stored RO permeate tanks. Destroys bacteria, biofilm slime, and odor without adding persistent chlorine taste—decomposing cleanly back into oxygen.

Common Size / Rating Options
3 g/hr10 g/hr

Application Scale & Replacement Verification

Scale: Commercial / IndustrialBrand: Axtron

Compare housing dimensions, port diameter, and membrane GPD capacity before ordering spares or requesting local dealer quotes. Verify System Fit in Water Planner →

Before You Install: Mount the ozone generator HIGHER than the maximum water tank level and fit BOTH a dry-trap bottle and stainless/PTFE check valve on the ozone tubing—back-flooded tank water instantly shorts out corona cells.

Key Technical Specs

System SeriesAxtron
Ozone Output10 g/hr O3
Application DutyCommercial / Industrial
Disinfection Spectrum254 nm Germicidal UV-C or Dissolved O3

Right Fit When

  • High-volume 3 to 10 Ton water filling stations, bulk storage silos, and bottling rinsers.
  • Stainless steel or HDPE permeate reservoirs requiring residual-free disinfection.

When To Skip or Double-Check

  • NEVER plumb ozone gas BEFORE an RO membrane—ozone oxidizes and shreds polyamide RO sheets far faster than chlorine; ALWAYS inject strictly post-RO into stainless or HDPE storage tanks.

Signs This Part Is Failing

  • Zero fresh ozone scent or bubbles at the tank diffuser stone while power light stays on
  • Water backing up inside the transparent ozone delivery hose toward the machine
  • Blown main fuse or high-voltage transformer buzz without ozone generation

Diagnostic Checklists If Something Goes Wrong

Step 1 · Check non-return check valve against tank water back-flooding

Is tank water climbing backward up the silicone/PTFE ozone hose toward the unit?

Disconnect the ozone hose at the generator outlet immediately and check whether the inline PTFE/Kynar check valve seals backward.

Common Questions

How long does ozone stay active in stored RO water?

Usually 20–40 minutes depending on temperature before reverting naturally back into pure oxygen—which is why bottling lines inject gently via continuous recirculation.

Can standard clear PVC tubing be used for ozone gas?

No—PVC turns brittle and cracks under concentrated ozone; always use silicone, PTFE, or stainless tubing.